Ignis Electrical Monitor
Forma et institutionem dimensionum
Productum notitia
Productum exemplar: NLK888DDS
Ratum operans current IN (A): 16A~ 1600A
Rated intentione UE (V): AC220V
Residua monetae monetae et terroris valoris: 20mA~1000mA pro lubitu erigi potest
Monitum et terrorem current tempus tres-valores: no
Temperatus admonitionem et terrorem pretii: 20°C~150°C pro lubitu constitui potest
Circuitus lacus numerus: circuitus 1~16
Numerus temperatus ansas: 1~8 loramenta
Terror praesidium: tutela vel nulla tutela potest
Tutela actio: ≤0.5S
Terrorem output: capacitatem contactus siccum AC220V/5A
Iter output: contactum siccum facultatem AC220V/5A
Iter alveum: 1~8 channels
Propono modus: digital digital propono
Ignis nexus: DC24V
Modus communicandi: CNA bus (≤10KM)
Terror sonus: ≤70dB
Temperatus ambiens: -20℃~+40℃
Altitude: non plus quam 3000M
Executive standard: GB142872-2005
GB14287.3-2005
Basic functiones
Ignis electricae vigilantia detector potest percipere real-time vigilantia et collectione residua currentis et temperaturae valoris ambitus moderati, et emittet terrorem insignem et audibilem et visualem culpam, cum culpa terror notitiae deprehensionis in circuitu colligitur;Potest etiam networked cum exercitu electrico ignis vigilantia, et exercitus vigilantia iudicare potest Status in-site detector, hospes computatorii analyses et processuum ad indicandum genus ambitus culpae terroris, et emittit audibilem et visualem. culpae terror signum.
Pelagus parametri technica
1. Ratum intentione laborantis: AC220V (AC85V-260V)
2. Residua vena terror range: 50-1000mA
3. Temperature terror range: 25-125℃
4. Praesidium tempus agendi: ≤0.5s
5. Terror sonus: 70db
6. Terror output: switch type, contactus capacitatis AC250V /3A
7. Modus et spatium Communicationis: duo-bus protocollum communicationis/≤1500m
8. Praesidium campester: IP 30
9. Executive standard: GB14287.2-2014
10. Environmentales condiciones ad usum: Ambiens temperatus: 0℃~+60℃
Relativum humiditatis: X% -90%
Institutionem ac Dimensiones
Wiring schematic schema
1. Figurae terminorum [specificationes diversorum productorum, munus terminalis reduci possunt].
2.Application Diagram
Nota: tria phase quattuor-filum transfigurans ex eadem directione transire debet
Institutionem ac Dimensiones
Wiring schematic schema
1. Figurae terminorum [specificationes diversorum productorum, munus terminalis reduci possunt].
2.Application Diagram
Nota: tria phase quattuor-filum transfigurans ex eadem directione transire debet
opus nomen | exemplar productum | basic munus | dicta | ||
Ignis coniunctus monitor | NLK888DDS | Function: digitalis ostensio, detectio currentis residua, temperatura, ignis input, communicatio, terror, supplantatio, etc.A lacus est;siccus t;k est fibula | Al/T4 | 155mm*l10mm*65mm | |
A4/T4 | |||||
A8/T4 | |||||
A4/T4/K4 | |||||
A8/T4/K8 | |||||
NLK888DDY | Munus: LCD propono, deprehendere residua current, temperatus ignis initus, communicationis terror, supplantat, etc. Aliquam est lacus;siccus t;k est fibula | Al/T4 | 179mm*l 00mm*77mm | ||
A4/T4 | |||||
A8/T4 | |||||
A16/T4 | |||||
A4/T4/K4 | |||||
A8/T4/K8 | |||||
Al6/T4/Kl |